How to Use Alarm Camera
1. The alarm camera’s LED light will open 20 seconds for self-test once connect the power, then close.
2. Then all operate steps like normal analog camera.
When the IR leds open at dark environment, if any intruder enters, strong LED light will irradiate the intruder for 20 seconds, if he keeps moving, the strong LED light will always irradiate him.
3. Detect level: Set the detect sense level(distance): OSD menu—Motion Det (ON)—Detect Sense
CCD Sensor: (default is 120, you can adjust from 0 to 127)
If<120 detect sensitivity is low, detect distance is short.
If>120 detect sensitivity is high, detect distance is long.
CMOS Sensor: (default is 70, you can adjust from 0 to 99)
If<70 detect sensitivity is low, detect distance is short.
If>70 detect sensitivity is high, detect distance is long.
4. Tracking signal:
If your alarm camera has OSD cable, you can set the tracking signal showing on your monitor. OSD menu—Motion Det (ON)—Block Disp (ON)
5. Siren function:
If your alarm camera has siren function, connect the siren to the OSD cable. When the white leds switch on, the siren will working, when the white leds switch off, the siren will switch off.
|